12Pressure redistributing devices

Publication Details

Pressure relieving and redistributing devices are widely accepted methods of trying to prevent the development of pressure ulcers for people considered as being at risk. The devices used include different types of mattresses, overlays, cushions and seating. These devices work by reducing or redistributing pressure, friction or shearing forces.

Selection of a device may depend on factors such as mobility of the individual, the results of skin assessment, the level of and site at risk, weight, staff availability and skill plus the general health and condition of the individual. It is also important that any device is able to be cleaned and decontaminated effectively. It is accepted that these devices should be used in conjunction with other preventative strategies such as repositioning.

Specific devices are available for certain at risk sites, for example, the heel. Pressure redistributing devices for heels are considered in Chapter 13.

The GDG were therefore interested in identifying whether the use of pressure redistributing devices, including both static and dynamic surfaces, are effective in the prevention of pressure ulcers.

12.1. Review question: What are the most clinically and cost-effective pressure re-distributing devices for the prevention of pressure ulcers?

For full details see review protocol in Appendix C.

12.1.1. Clinical evidence (adults)

A Cochrane review by McInnes et al (2011)127 was identified from the search and was adapted for this review. The Cochrane review was quality assured and, as it was of very high quality and matched the majority of the protocol (see Appendix C), the information was used to populate this review for the summary of studies, forest plots and for the quality assessment of studies (see Appendix G-I). Fifty-three studies were included in the Cochrane review. Three studies were removed but used in the review on the use of pressure redistributing devices for the prevention of heel pressure ulcers28,71,207 as they included devices which are specific to only heel ulcers (see Chapter 13). One study60 was at high risk of bias and did not report outcomes clearly and was excluded (from our review and the Cochrane review). One other study (Economides, 1995)58 was excluded as it looked at wound breakdown rather than incidence of pressure ulcers. Two other studies (Gentilello, 198869 and Summer, 1989195) were excluded from this review as they were more relevant to the repositioning review (see Chapter 9). Eight other studies27,30,54,82,125,163,209,217 which were not included in the Cochrane review, were identified and included in this review (see Appendix G).

In total, 54 studies were included in this review 3,6,15,31,33,35,38-40,42,48,61,62,70,72,76,77,83,87,90,94,101,103,104,113,114,117,126,130,148,14927,30,54,68,82,125,161,163-165,172,174,180,185,192,198-200,209,214,217,218,223. Evidence from these studies is summarised in the clinical GRADE evidence profiles below.

See also the study selection flow chart in Appendix D, forest plots in Appendix I, study evidence tables in Appendix G and exclusion list in Appendix J.

In the studies, various types of devices were used to redistribute pressure to prevent pressure ulcers. The Cochrane review categorised them as low-tech (non-powered) constant low pressure support surfaces, high-tech support surfaces and other support surfaces. The types of devices included are listed below;

  • ‘Low-tech’ continuous low pressure (CLP) support surfaces:
    • Standard foam mattresses.
    • Alternative foam mattresses/overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Gel-filled mattresses/overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Fibre-filled mattresses/overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Air-filled mattresses/overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Water-filled mattresses/overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Bead-filled mattresses/overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Sheepskins
  • ‘High-tech’ support surfaces:
    • Alternating-pressure mattresses/overlays: air-filled sacs that inflate and deflate sequentially to relieve pressure at different anatomical sites for short periods; these may incorporate a pressure sensor
    • Air-fluidised beds: warmed air circulates through fine ceramic beads covered by a permeable sheet; allowing support over a larger contact area (CLP)
    • Low-air-loss beds: support provided by a series of air sacs through which warmed air passes (CLP)
  • Other support surfaces:
    • Turning beds/frames: aides manual repositioning of the patient, or by motor driven turning and tilting.
    • Operating table overlays: conformable and aim to redistribute pressure over a larger contact area.
    • Wheelchair cushions: either conforming cushions that reduce contact pressures by increasing surface area in contact, or mechanical cushions which alternate pressure.
    • Limb protectors: pads and cushions of different forms to protect bony prominences.
    The Cochrane review considered all studies, regardless of whether grade 1 pressure ulcers were described separately, although the authors state that studies comparing the incidence of pressure ulcers of grade 2 or greater are more likely to be reliable. For the purposes of the current review, the GDG therefore chose to include pressure ulcers of grade 2 and above were.

Although the included studies used a range of grading systems, those which reported pressure ulcers of grade 2 and above separately, used the EPUAP or NPUAP classification system (see Table 50). For studies that did not use the EPUAP/NPUAP and reported grade of ulcer separately, the distinction was usually a break in the skin or blister.

Table 50. Glossary of terms (NPUAP 2007).

Table 50

Glossary of terms (NPUAP 2007).

The Cochrane review reported that methods of measuring secondary outcomes such as comfort, durability, reliability and acceptability were not well developed. Where data were presented details were provided, but this was not incorporated into the analysis. As some of these outcomes were considered by the GDG to be critical for decision making, for the purposes of this review these outcomes have been included in the GRADE evidence tables (see Table 52).

The Cochrane review meta-analysed studies where there was more than 1 trial for an outcome which compared similar devices. The results were pooled using a fixed effect model, but if heterogeneity (I2 = 50% or above and the p value was less than 0.10) was found, a random-effects model was used. The review states that it was assumed that the risk ratio remained constant for different lengths of follow-up and so results were pooled if participants were followed-up for different lengths of time.

No studies were found for standard or pressure-relieving chairs, tilt-in-space wheelchairs, postural support or limb protectors.

Summary of included studies

Table 51. Summary of included studies.

Table 51

Summary of included studies.

12.1.2. ‘Low-tech’ constant low-pressure (CLP) supports

The Cochrane review compared standard foam hospital mattresses with other low specification (‘low-tech’), constant low-pressure (CLP) supports. Sheepskin, static air-filled supports; water-filled supports; contoured or textured foam supports; gel-filled supports; bead-filled supports; fibre-filled supports, and alternative foam mattresses or overlays were considered to be low-tech CLP. However it is noted that there is not an international definition of what a standard foam mattress is. In addition the definition can change over time, within countries, and even within hospitals. If a description of the standard mattress was given it was included in the review, which is outlined in Table 51. The Cochrane review assumes that standard mattresses are likely to vary less within countries than between countries, and undertook subgroup analysis by country, although this intention was not pre-specified.

12.1.2.1. Standard foam hospital mattress compared with other “low-tech” CLP

Table 52. Clinical evidence profile: constant low-pressure supports (CLP) versus standard foam mattresses (SFM) for pressure ulcer prevention.

Table 52

Clinical evidence profile: constant low-pressure supports (CLP) versus standard foam mattresses (SFM) for pressure ulcer prevention.

Table 53. Clinical evidence profile: constant low pressure support (inflated static overlay (ISO)) versus constant low pressure support (microfluid static overlay (MSO)) and alternating pressure support (low-air-loss dynamic mattress (LALDM)).

Table 53

Clinical evidence profile: constant low pressure support (inflated static overlay (ISO)) versus constant low pressure support (microfluid static overlay (MSO)) and alternating pressure support (low-air-loss dynamic mattress (LALDM)).

Table 54. Clinical evidence profile: alternative foam mattress versus standard foam mattress.

Table 54

Clinical evidence profile: alternative foam mattress versus standard foam mattress.

12.1.3. Comparisons between alternative foam mattresses

Table 55. Clinical evidence profile: comparisons between alternative foam supports.

Table 55

Clinical evidence profile: comparisons between alternative foam supports.

12.1.4. Comparisons between ‘low-tech’ constant low-pressure supports

Table 56. Clinical evidence profile: comparisons between CLP supports.

Table 56

Clinical evidence profile: comparisons between CLP supports.

12.1.5. ‘High-tech’ pressure supports

This section outlines 3 main groups of supportsL alternating pressure devices (AP), low-air loss beds and air-fluidised low beds.

12.1.5.1. Alternating-pressure compared with constant low pressure

Table 57. Clinical evidence profile: alternating-pressure versus standard foam mattress.

Table 57

Clinical evidence profile: alternating-pressure versus standard foam mattress.

12.1.5.2. Alternating-pressure compared with constant low pressure

Table 58. Clinical evidence profile: alternating-pressure versus constant low-pressure.

Table 58

Clinical evidence profile: alternating-pressure versus constant low-pressure.

Table 59. Clinical evidence profile: alternating pressure and constant low pressure in ICU/post ICU (factorial design).

Table 59

Clinical evidence profile: alternating pressure and constant low pressure in ICU/post ICU (factorial design).

Table 60. Clinical evidence profile: standard mattress in ICU/standard foam mattress post-ICU versus standard ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 60

Clinical evidence profile: standard mattress in ICU/standard foam mattress post-ICU versus standard ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 61. Clinical evidence profile: alternating pressure (NIMBUS) ICU/SFM post-ICU versus standard ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 61

Clinical evidence profile: alternating pressure (NIMBUS) ICU/SFM post-ICU versus standard ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 62. Clinical evidence profile: standard ICU/standard foam mattress post-ICU versus slternating pressure mattress (NIMBUS) ICU/constant low pressure mattress (TEMPUR)CLP post-ICU – grade 2 and above pressure ulcers.

Table 62

Clinical evidence profile: standard ICU/standard foam mattress post-ICU versus slternating pressure mattress (NIMBUS) ICU/constant low pressure mattress (TEMPUR)CLP post-ICU – grade 2 and above pressure ulcers.

Table 63. Clinical evidence profile: alternating pressure mattress (NIMBUS) ICU/standard foam mattress post-ICU versus alternating pressure mattress (NIMBUS) ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 63

Clinical evidence profile: alternating pressure mattress (NIMBUS) ICU/standard foam mattress post-ICU versus alternating pressure mattress (NIMBUS) ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 64. Clinical evidence profile: standard ICU/constant low pressure mattress (TEMPUR) post-ICU versus alternating pressure mattress (NIMBUS) ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

Table 64

Clinical evidence profile: standard ICU/constant low pressure mattress (TEMPUR) post-ICU versus alternating pressure mattress (NIMBUS) ICU/constant low pressure mattress (TEMPUR) post-ICU – grade 2 and above pressure ulcers.

12.1.6. Comparisons between different alternating-pressure devices

Table 65. Clinical evidence profile: comparisons between alternating-pressure devices.

Table 65

Clinical evidence profile: comparisons between alternating-pressure devices.

12.1.7. Low-air-loss (LAL) beds

Three studies evaluated the use of low-air-loss beds. Such devices provide a flow of air that assists in controlling the microclimate of the person's skin (NPUAP 2007).20 Two studies (Inman 1993 and Cobb 1997) were pooled as they included people in ICU.33,93 A further study (Bennett) considered a low-air-loss hydrotherapy bed compared to a variety of mattresses which was not in people in ICU, and therefore was not pooled.14

12.1.7.1. Comparisons between LAL and other devices

Table 66. Clinical evidence profile: low air loss versus standard bed.

Table 66

Clinical evidence profile: low air loss versus standard bed.

12.1.8. Other devices

12.1.8.1. Operating room mattress

Table 67. Clinical evidence profile: indentation load deflection (IDL) (25%) operating room foam mattress (density 1.3 cubic feet, IDL 30lb) versus operating room usual care (padding as required, including gel pads, foam mattresses, ring cushions).

Table 67

Clinical evidence profile: indentation load deflection (IDL) (25%) operating room foam mattress (density 1.3 cubic feet, IDL 30lb) versus operating room usual care (padding as required, including gel pads, foam mattresses, ring cushions).

12.1.8.2. Operating table overlay

Table 68. Clinical evidence profile: operating table overlay versus no overlay.

Table 68

Clinical evidence profile: operating table overlay versus no overlay.

12.1.8.3. Face pillows in the operating theatre

Table 69. Clinical evidence profile: disposable polyurethane foam prone head positioner (OSI) versus neoprene air filled bladder (dry flotation) device (ROHO).

Table 69

Clinical evidence profile: disposable polyurethane foam prone head positioner (OSI) versus neoprene air filled bladder (dry flotation) device (ROHO).

Table 70. Clinical evidence profile: disposable polyurethane foam prone head positioner (OSI) versus prone view protective helmet system with a disposable polyurethane foam prone head positioner (DUPACO).

Table 70

Clinical evidence profile: disposable polyurethane foam prone head positioner (OSI) versus prone view protective helmet system with a disposable polyurethane foam prone head positioner (DUPACO).

Table 71. Clinical evidence profile: neoprene air filled bladder (dry flotation) device (ROHO) versus prone view protective helmet system with a disposable polyurethane foam prone head positioner (DUPACO).

Table 71

Clinical evidence profile: neoprene air filled bladder (dry flotation) device (ROHO) versus prone view protective helmet system with a disposable polyurethane foam prone head positioner (DUPACO).

Table 72. Clinical evidence profile: multi-cell pulsating dynamic mattress system (MICROPULSE) versus standard mattress for people undergoing surgery.

Table 72

Clinical evidence profile: multi-cell pulsating dynamic mattress system (MICROPULSE) versus standard mattress for people undergoing surgery.

Table 73. Clinical evidence profile: viscoelastic foam (TEMPUR-PEDIC) A&E overlay and ward mattress versus standard A&E overlay and ward mattress.

Table 73

Clinical evidence profile: viscoelastic foam (TEMPUR-PEDIC) A&E overlay and ward mattress versus standard A&E overlay and ward mattress.

12.1.9. Profiling beds

12.1.9.1. Comparison between profiling bed and flat-based bed

Table 74. Clinical evidence profile: profiling bed with a pressure-reducing foam mattress versus flat-based bed with a pressure-reducing mattress.

Table 74

Clinical evidence profile: profiling bed with a pressure-reducing foam mattress versus flat-based bed with a pressure-reducing mattress.

12.1.10. Seat cushions

12.1.10.1. Comparison between different cushions

Table 75. Clinical evidence profile: comparisons between different seat cushions.

Table 75

Clinical evidence profile: comparisons between different seat cushions.

12.1.11. Economic evidence (adults)

Published literature

Nine studies were included with relevant comparisons.65,96,115,131,149,159,160,167,217 These are summarised in the economic evidence profiles below (Table 76 - Table 80). See also the study selection flow chart in Appendix D and study evidence tables in Appendix G.

Table 76. Economic evidence profile: alternating pressure verses alternative foam.

Table 76

Economic evidence profile: alternating pressure verses alternative foam.

Table 77. Economic evidence profile: comparisons between alternating pressure devices.

Table 77

Economic evidence profile: comparisons between alternating pressure devices.

Table 78. Economic evidence profile: high specification foam verses standard practice.

Table 78

Economic evidence profile: high specification foam verses standard practice.

Table 79. Economic evidence profile: constant low pressure supports compared to standard care.

Table 79

Economic evidence profile: constant low pressure supports compared to standard care.

Table 80. Economic evidence profile: constant low pressure supports compared to standard care in operating theatre.

Table 80

Economic evidence profile: constant low pressure supports compared to standard care in operating theatre.

Four studies that met the inclusion criteria were selectively excluded due to methodological limitations and availability of more applicable evidence.13,92,93,206 These are summarised in Appendix K, with reasons for exclusion given.

Six further studies were found which included devices for the prevention of pressure ulcers as part of more complex prevention strategies.121,124,153,202,226,227 These studies were not included as they evaluated the cost-effectiveness of the prevention strategies as a whole, and did not provide information on the cost-effectiveness of the devices alone.

It is clear from Table 77 that 2 of the included studies65,149 demonstrate conflicting results, despite both being conducted from the perspective of the UK NHS, with costs based on 2003 UK prices. Nixon and colleagues found that alternating pressure replacement mattresses (AR) dominate alternating pressure overlays (AO), whilst Fleurence found that AOs are cost effective. Both studies indicate that ARs have a greater effectiveness, with Nixon reporting greater time to pressure ulcer development and Fleurence a small increase in QALYs associated with an increase in pressure ulcer free days. However, the incremental pressure ulcer free days in Nixon are 10 times greater than those reported in Fleurence. This is most likely due to the different methods of collecting effectiveness data (Nixon is based on a within trial analysis whilst Fleurence is based on an estimation validated by experts) and the 2 different approaches to modelling (a regression analysis to calculate additional costs and pressure ulcer free days in Nixon, and a decision tree in Fleurence). Unit costs of devices presented in these 2 papers are almost identical, both obtained from Huntleigh Healthcare and reported in 2003 prices, yet Fleurence assumes a 2 year time horizon for overlays and an 8 year horizon for mattresses, whilst Nixon and colleagues assume a 2 year time horizon for both devices. Of note, a zero cost of pressure ulcer management is assumed in Nixon, whilst a value of £1,133 is used to represent this cost in Fleurence. There are also differences in assumptions surrounding the proportion of mattresses that were rented or purchased.

Unit costs

The following unit costs were presented to aid consideration of cost effectiveness (Table 81).

Table 81. Unit costs.

Table 81

Unit costs.

Note - these prices have been obtained directly from manufacturers, and represent the list price for the NHS. It is acknowledged that prices vary locally, therefore these prices are illustrative only. The devices included in the table are those identified by GDG members as being commonly used, and should not be interpreted as recommended devices.

12.1.12. Clinical evidence (neonates, infants, children and young people)

No RCTs or cohort studies were identified. Recommendations were developed using a modified Delphi consensus technique. Further details can be found in Appendix N.

12.1.13. Economic evidence (neonates, infants, children and young people)

Published literature

No relevant economic evaluations were identified.

Economic considerations

In the absence of economic evidence, the GDG considered relevant UK NHS unit costs of various mattresses and overlays (Table 82) These were considered alongside clinical evidence obtained from the Delphi consensus panel to inform qualitative judgement about cost-effectiveness.

Table 82. Unit costs.

Table 82

Unit costs.

12.1.14. Evidence statements

12.1.14.1. Clinical (adults)

12.1.14.1.1. Cubed foam mattress (COMFORTEX DECUBE) versus standard hospital mattress (standard polypropylene SG40)
  • One study (n=44) showed a cubed foam mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2-4) when compared to a standard hospital mattress (very low quality).
  • One study (n=44) showed a cubed foam mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard hospital mattress (very low quality).
  • One study (n=44) reported medians for a cubed foam mattress and standard hospital mattress for length of stay in hospital. The median for a cubed foam mattress was 21 days (range 5-64) and 23 days (range 4-120) for the standard hospital mattress. No estimate for effect or precision could be derived (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Health-related quality of life
12.1.14.1.2. Bead filled mattress (BEAUFORT) versus standard hospital mattress
  • One study (n=75) showed a bead filled mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard foam mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.3. Softform mattress versus standard 130mm NHS foam mattress
  • One study (n=170) showed a softform mattress is more clinically effective at reducing the incidence of pressure ulcers (grade 2-4) when compared to a standard 130mm NHS foam mattress (low quality).
  • One study (n=170) showed there is no clinical difference between a softform mattress and a standard 130mm NHS foam mattress for perception of comfort being very uncomfortable (low quality).
  • One study (n=170) showed there may be no clinical difference between a softform mattress and a standard 130mm NHS foam mattress for perception of comfort being uncomfortable, but the direction of the estimate of effect favoured the softform mattress (very low quality).
  • One study (n=170) showed a softform mattress is more clinically effective for perception of comfort being adequate when compared to a standard 130mm NHS foam mattress (low quality).
  • One study (n=170) showed a softform mattress is more clinically effective for perception of comfort being comfortable when compared to a standard 130mm NHS foam mattress (low quality).
  • One study (n=170) showed a softform mattress is more clinically effective for perception of comfort being very comfortable when compared to a standard 130mm NHS foam mattress (low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.4. Water-filled mattress versus standard hospital mattress
  • One study (n=316) showed a water-filled mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard hospital mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.5. Alternative foam pressure-reducing mattress (CLINIFLOAT, OMNIFORM, SOFTFORM, STM5, THERAREST, TRANSFOAM, VAPOURLUX) versus standard hospital mattress
  • Two studies (n=696) showed an alternative foam pressure-reducing mattress is more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard hospital mattress (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.6. High-specification foam mattress (visco-polymer energy absorbing foam mattress (CONFORM-ED) versus standard mattress (KING's FUND, LINKNURSE, SOFTFOAM, TRANSFOAM, KING's FUND MATTRESS with a SPENCO or PROPAD overlay)
  • One study (n=1166) showed there is potentially no clinical difference between a high-specification foam mattress and a standard mattress for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the high-spec foam mattress (very low quality).
  • One study (n=706) showed there is no clinical difference between a high-specification foam mattress and a standard mattress for perception of comfort , the direction of the estimate of effect favoured the standard mattress (low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.7. Inflated static overlay versus microfluid static overlay and low-air-loss dynamic mattress
  • One study (n=110) showed there may be a clinical benefit for a constant low-pressure support (inflated static overlay) compared to a constant low-pressure support (microfluid static overlay) and alternating-pressure support (low-air-loss dynamic mattress) for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • One study (n=64) showed there is no clinical benefit of a constant low-pressure support (inflated static overlay) for patient acceptability (comfort) when compared with a constant low-pressure support (microfluid static overlay) and alternating-pressure support (low-air-loss dynamic mattress) (moderate quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.8. Alternative foam mattress versus standard foam mattress
  • Five studies (n=2016) showed an alternative foam mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard foam mattress (very low quality).
  • Four UK studies (n=1980) showed an alternative foam mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard foam mattress (very low quality).
  • Two studies (n=206) showed an alternative foam mattress is more clinically effective at reducing the incidence of pressure ulcers (grade 2-4) when compared to a standard foam mattress (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.9. Pressure redistributing mattress (CLINIFLOAT, OMNIFOAM, THERAREST, TRANSFOAM, VAPERM) versus standard NHS foam mattress (REYLON 150mm)
  • One study (n=505) showed a pressure redistributing mattress is more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to standard NHS foam mattress (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.10. Foam mattress replacement (MAXIFLOAT) versus foam mattress overlay (IRIS 3000)
  • One study (n=40) showed a foam mattress replacement (Maxifloat) is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a foam mattress overlay (very low quality).
  • One study (n=40) showed a foam mattress replacement (Maxifloat) is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to a foam mattress overlay (very low quality).
  • One study (n=40) reported means for a foam mattress replacement (Maxifloat) and foam mattress overlay for time to develop new pressure ulcers. The median for a foam mattress replacement (Maxifloat) was 9.2 days and 6.5 days (range 4-120) for the foam mattress overlay. No estimate for effect or precision could be derived. (very low quality)
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.11. Solid foam overlay versus convoluted foam overlay
  • One study (n=84) showed a solid foam overlay is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a convoluted foam overlay (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.12. Pressure-reducing foam mattress (TRANSFOAM) versus pressure-reducing foam mattress (TRANSFOAMWAVE)
  • One study (n=100) showed there may be no clinical difference between a pressure-reducing TRANSFOAM foam mattress and a pressure-reducing TRANSFOAMWAVE foam mattress for reducing the incidence of pressure ulcers (all grades), but the direction of the estimate of effect could favour either intervention (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.13. Constant low-pressure mattress (CARITAL OPTIMA) versus standard foam mattress (10cm thick foam density 35kg/m3)
  • One study (n=40) showed a constant low-pressure mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard foam mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.14. Dry flotation mattress (SOFFLEX) versus dry flotation mattress (ROHO)
  • One study (n=84) showed there may be a clinical benefit for a SOFFLEX dry flotation mattress compared to a ROHO dry flotation mattress for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • One study (n=84) showed that there may not be a clinical benefit of a ROHO dry flotation mattress compared to a SOFFLEX dry flotation mattress for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • One study (n=84) showed there is no clinical difference between a SOFFLEX dry flotation mattress and a ROHO dry flotation mattress for patient acceptability (perception of comfort being very uncomfortable) (moderate quality).
  • One study (n=84) showed a SOFFLEX dry flotation mattress is potentially more clinically effective for patient acceptability (perception of comfort being uncomfortable) when compared to a ROHO dry flotation mattress (low quality).
  • One study (n=84) showed there may be no clinical difference between a SOFFLEX dry flotation mattress and a ROHO dry flotation mattress for patient acceptability (perception of comfort being adequate), but the direction of the estimate of effect could favour either intervention (very low quality).
  • One study (n=84) showed there may be no clinical difference between a SOFFLEX dry flotation mattress and a ROHO dry flotation mattress for patient acceptability (perception of comfort being comfortable), but the direction of the estimate of effect could favour either intervention (very low quality).
  • One study (n=84) showed there may be no clinical difference between a SOFFLEX dry flotation mattress and a ROHO dry flotation mattress for patient acceptability (perception of comfort being very comfortable), but the direction of the estimate of effect could favour either intervention (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.15. Gel mattress versus air-filled overlay (SOFCARE)
  • One study (n=66) showed there may be a clinical benefit for a gel mattress compared to an air-filled overlay for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • One study (n=66) showed there may be a clinical benefit for a gel mattress compared to an air-filled overlay for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.16. Static air mattress (GAY MAR SOFCARE) versus water mattress (LOTUS PXM 3666)
  • One study (n=37) showed there may be a clinical benefit for a water mattress compared to a static air mattress for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.17. Inflated static overlay (RIK or THERAKAIR) versus microfluid static overlay
  • One study (n=105) showed there may be a clinical benefit for an inflated static overlay compared to a microfluid static overlay for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.18. Foam overlay versus Silicore overlay (SPENCO)
  • One study (n=68) showed there may be a clinical benefit of a Silicore overlay compared to a foam overlay for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.19. Australian medical sheepskin versus no sheepskin
  • Three studies (n=1281) showed Australian medical sheepskin is more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to no sheepskin (very low quality).
  • Three studies (n=1281) showed there is potentially no clinical difference between an Australian medical sheepskin and no sheepskin for reducing the incidence of pressure ulcers (grade 2 and above), the direction of the estimate of effect favoured the Australian medical sheepskin (very low quality).
  • One study (n=539) reported 10 participants in the sheepskin group complained about its comfort. The clinical importance is unknown (very low quality).
  • One study (n=297) reported 6 participants in the sheepskin group withdrew before study completion due to the sheepskin causing irritation, was too hot or uncomfortable. The clinical importance is unknown (very low quality).
  • One study (n=539) reported a clinical benefit of Australian medical sheepskin when compared to no sheepskin for delaying the time to develop new pressure. The hazard ratio was 0.39 (95% CI 0.22 -0.69; p<0.001) (very low quality).
  • One study (n=543) reported a clinical benefit for Australian medical sheepskin when compared to no sheepskin for delaying the time to develop new pressure ulcers. The mean for Australian medical sheepskin was 12 days and 9 days for no sheepskin. No estimate of clinical effect or precision could be derived (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.20. Static air overlay and cold foam mattress versus cold foam mattress alone
  • One study (n=74) showed a static air overlay and cold foam mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to a cold foam mattress alone (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.21. 3D macroporous polyester overlay versus visco-elastic overlay
  • Two studies (n=122) showed there is potentially no clinical difference between a macroporous polyester overlay and a visco-elastic overlay for reducing the incidence of pressure ulcers, the direction of the estimate of effect favoured the macroporous polyester overlay (low quality).
12.1.14.1.22. Alternating-pressure versus standard foam mattress
  • Two studies (n=409) showed an alternating-pressure air mattress is more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard foam mattress (low quality).
  • One study (n=82) showed an alternating-pressure air mattress is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to a standard foam mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.23. Alternating-pressure versus constant low-pressure for pressure ulcer prevention
  • Eleven studies (n=1622) showed alternating-pressure is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to constant low-pressure (very low quality).
  • Six studies (n=826) showed alternating-pressure is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to constant low-pressure (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.24. Alternating pressure (various devices) versus constant low pressure (various devices)
  • One study (n=230) showed an alternating-pressure mattress is more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a constant low-pressure mattress (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.25. Alternating-pressure versus Silicore or foam overlay
  • Four studies (n=331) showed there is potentially no clinical difference between alternating-pressure and a Silicore or foam overlay for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the alternating-pressure mattress (very low quality).
  • Two studies (n=180) showed that, for people with chronic neurological conditions, there is potentially no clinical difference between an alternating-pressure overlay and a silicore overlay for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the alternating-pressure mattress (very low quality).
  • Two studies (n=151) showed that, for people without chronic neurological conditions, there may be no clinical difference between an alternating-pressure mattress and silicore or foam overlay for reducing the incidence of pressure ulcers (all grades) but the direction of the estimate of effect could favour either intervention (very low quality).
  • One study (n=187) showed that there may not be a clinical difference between a silicore overlay when compared to an alternating-pressure overlay for patient acceptability (drop out due to discomfort), but the direction of the estimate of effect could favour the silicore overlay (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.26. Alternating-pressure versus water or static air mattress
  • Three studies (n=458) showed there may be no clinical difference between alternating-pressure and water or static air mattress for reducing the incidence of pressure ulcers (all grades) but the direction of the estimate of effect could favour the water or static air mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.27. Alternating-pressure setting on mattress (DUO2) versus continuous low-pressure setting on mattress (DUO2)
  • One study (n=140) showed there may be no clinical difference between a continuous low-pressure setting on mattress and an alternating-pressure setting on mattress for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured continuous low-pressure setting on mattress (very low quality).
  • One study (n=170) reported that there was no difference in length of stay related to pressure ulcer development among people at high-risk placed on the intervention or control mattresses. The clinical importance is unknown. (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.28. Alternating-pressure air mattress (ALPHA-X-CELL) versus visco-elastic foam mattress (TEMPUR)
  • One study (n=447) showed there may be no clinical difference between alternating-pressure air mattress and visco-elastic foam mattress for the incidence of pressure ulcers (all grades) but the direction of the estimate of effect could favour the visco-elastic foam mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.29. Alternating-pressure mattress (NIMBUS 3) versus dry flotation mattress overlay (ROHO)
  • One study (n=16) showed there may be no clinical difference between an alternating-pressure mattress and a dry flotation mattress overlay for reducing the incidence of pressure ulcers (all grades), but the direction of the estimate of effect could favour either intervention (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.30. Dynamic flotation mattress (NIMBUS2) and alternating-pressure cushion versus low-pressure inflatable mattress (REPOSE SYSTEM) and cushion (polyurethane)
  • One study (n=50) showed there may be no clinical difference between dynamic flotation mattress with alternating-pressure cushion and low-pressure inflatable mattress and cushion for reducing the incidence of pressure ulcers (grade 2 and above), but the direction of the estimate of effect could favour either intervention (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.31. Standard foam mattress in ICU/Standard foam mattress post-ICU versus Alternating-pressure mattress (NIMBUS) in ICU/Standard foam mattress post-ICU
  • One study (n=160) showed no clinical difference between a standard foam mattress in ICU followed by a standard foam mattress post-ICU and an alternating-pressure mattress in ICU followed by a standard foam mattress post-ICU for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the standard foam mattress in ICU followed by a standard foam mattress post-ICU (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.32. Standard mattress in ICU/Standard foam mattress post-ICU versus Standard foam mattress ICU/constant low-pressure mattress (TEMPUR) post-ICU
  • One study (n=155) showed there may be no clinical difference between a standard foam mattress in ICU followed by a constant low-pressure mattress post-ICU and a standard foam mattress in ICU followed by a standard foam mattress post-ICU for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured standard foam mattress in ICU followed by a constant low-pressure mattress post-ICU (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.33. Alternating-pressure mattress (NIMBUS) in ICU/Standard foam mattress post-ICU versus Standard foam mattress ICU/constant low-pressure mattress (TEMPUR) post-ICU
  • One study (n=155) showed there may be no clinical difference between an alternating-pressure mattress in ICU followed by a standard foam mattress post-ICU and a standard foam mattress in ICU followed by a constant low-pressure mattress post-ICU for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the alternating-pressure mattress in ICU (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.34. Standard foam mattress in ICU/Standard foam mattress post-ICU versus Alternating-pressure mattress (NIMBUS) in ICU/ constant low-pressure mattress (TEMPUR) post-ICU
  • One study (n=157) showed there may be no clinical difference for a standard foam mattress in ICU followed by a standard foam mattress post-ICU and an alternating-pressure mattress in ICU followed by a constant low-pressure mattress post-ICU for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the standard foam mattress in ICU followed by a standard foam mattress post-ICU (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.35. Alternating-pressure mattress (NIMBUS) in ICU/Standard foam mattress post-ICU versus alternating-pressure mattress (NIMBUS) in ICU/constant low-pressure mattress (TEMPUR) post-ICU
  • One study (n=157) showed there may be no difference for an alternating-pressure mattress in ICU followed by a standard foam mattress post-ICU compared to an alternating-pressure mattress in ICU followed by a constant low-pressure mattress post-ICU for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.36. Standard foam mattress ICU/constant low-pressure mattress (TEMPUR) post-ICU versus alternating-pressure mattress (NIMBUS) in ICU/ constant low-pressure mattress (TEMPUR) post-ICU
  • One study (n=142) showed there may be no clinical difference for a standard foam mattress in ICU followed by a constant low-pressure mattress post-ICU compared to an alternating-pressure mattress in ICU followed by a constant low-pressure mattress post-ICU for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.37. Alternating-pressure mattress with 2 layers of air cells (PEGASUS AIRWAVE SYSTEM) versus alternating-pressure large cell ripple mattress
  • One study (n=62) showed an alternating-pressure mattress with 2 layers of air cells is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to an alternating-pressure large cell ripple mattress (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.38. Alternating-pressure mattress (PEGASUS AIRWAVE SYSTEM) versus alternating-pressure mattress (PEGASUS CAREWAVE SYSTEM)
  • One study (n=75) showed there is no clinical difference between a Pegasus airwaves alternating-pressure mattress system and a Pegasus care wave alternating-pressure mattress system for reducing the incidence of pressure ulcers (grade 2 and above) (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.39. Alternating-pressure mattress (TRINOVA) versus control
  • One study (n=44) showed there may be a clinical benefit for a Trinova alternating-pressure mattress compared to a control for reducing the incidence of pressure ulcers (all grades) (very low or moderate quality).
  • One study (n=44) showed there may be a clinical benefit for a Trinova alternating-pressure mattress compared to a control for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • One study (n=44) reported data for the Trinova alternating-pressure mattress for patient acceptability (comfort). 11/18 participant thought the mattress was comfortable, 10/18 participants thought that the mattress was acceptable and 5/18 found the mattress comfort unacceptable. No estimate of effect or precision could be derived (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.40. Alternating-pressure overlay versus alternating-pressure mattress
  • One study (n=1971) showed there is potentially no difference for an alternating-pressure mattress alternating-pressure overlay compared to for reducing the incidence of pressure ulcers (grade 2 and above) (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.41. Alternating-pressure bed (THERAPULSE) versus alternating-pressure mattress (HILL-ROM DUO)
  • One study (n=62) showed there may be a clinical benefit for an alternating-pressure THERAPULSE bed compared to an alternating-pressure (HILL-ROM DUO) mattress for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • One study (n=62) reported means for an alternating-pressure THERAPULSE bed and an alternating-pressure (HILL-ROM DUO) mattress for length of stay in hospital for people who developed a pressure ulcer. The mean for an alternating-pressure (HILL-ROM DUO) mattress was 26 days (range 23-37.3) and 24 days (range 13-59) for an alternating-pressure (HILL-ROM DUO) mattress. No estimate for effect or precision could be derived (very low quality).
  • One study (n=62) reported means for an alternating-pressure THERAPULSE bed and an alternating-pressure (HILL-ROM DUO) mattress for length of stay in hospital for people who did not develop a pressure ulcer. The mean for an alternating-pressure (HILL-ROM DUO) mattress was 18 days (range 5-127) and 20 days (range 5-49) for an alternating-pressure (HILL-ROM DUO) mattress. No estimate for effect or precision could be derived (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Health related quality of life
12.1.14.1.42. Alternating low-pressure air mattress with multi-stage inflation and deflation of air cells versus standard (CLINACTIV, HILLROM) alternating low-pressure air mattress with single-stage inflation and deflation of air cells
  • One study (n=610) showed there is potentially no clinical difference between an alternating low-pressure air mattress with single-stage inflation and deflation of air cells compared to an alternating low-pressure air mattress with multi-stage inflation and deflation of air cells for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the low-pressure air mattress with single-stage inflation and deflation of air cells (very low quality).
  • One study (n=610) showed there may be no clinical difference between an alternating low-pressure air mattress with multi-stage inflation and deflation of air cells and an alternating low-pressure air mattress with single-stage inflation and deflation of air cells for reducing the incidence of pressure ulcers (grade 2 and above), but the direction of the estimate of effect could favour either intervention (very low quality).
  • One study (n=610) showed there may be a clinical benefit for an alternating low-pressure air mattress with multi-stage inflation and deflation of air cells compared to an alternating low-pressure air mattress with single-stage inflation and deflation of air cells for patient acceptability (withdrawal due to discomfort) (very low quality).
  • One study (n=610) reported a benefit for an alternating low-pressure air mattress with multi-stage inflation and deflation of air cells compared to an alternating low-pressure air mattress with single-stage inflation and deflation of air cells for time to develop a new pressure ulcer. The medians for an alternating low-pressure air mattress with multi-stage inflation and deflation of air cells was 5.0 days (Interquartile range 3.0-8.5) and 8 days (interquartile range 3.0 8.5) for an alternating low-pressure air mattress with single-stage inflation and deflation of air cells. No estimate of clinical effect or precision could be derived (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.43. Low-air-loss bed (KINAIR/THERAKAIR) versus static air mattress overlay/inflated static overlay (EHOB WAFFLE) or standard ICU bed
  • One study (n=123) showed a low-air-loss bed is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a static air mattress overlay (very low quality).
  • Two studies (n=183) showed there may be a clinical benefit for a low-air-loss bed compared to static air mattress overlay/inflated static overlay for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • Two studies (n=221) showed a low-air-loss bed is more clinically effective at reducing the incidence of pressure ulcers (grade 2and above)when compared to a static air mattress overlay or standard ICU bed (low quality).
  • One study (n=98) showed a low air loss hydrotherapy bed is more clinically effective at reducing the incidence of people developing multiple ulcers when compared to a standard care (standard bed or foam, air or alternating-pressure mattress) (low quality).
  • Three studies (n=319) showed a low-air-loss bed is more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to static air mattress overlay/standard ICU bed or standard care (standard bed or foam, air or alternating-pressure mattress) (low quality).
  • One study (n=98) reported some information about patient acceptability (comfort) for the low air loss hydrotherapy mattress. 10/42 provided information about comfort, of these 5/10 participants though it was comfortable and 4/10 participants thought it was uncomfortable. The clinical importance is unknown (very low quality).
  • One study (n=98) reported some information about patient acceptability (withdrawal from the study) for the low air loss hydrotherapy mattress compared with standard care (standard bed or foam, air or alternating-pressure mattress). In the low air loss hydrotherapy mattress group, 24/48 participantstients withdrew from the study, 6 on the first day of the study because a participant or family member complained about the bed (wet, cold or uncomfortable). In the standard care group 2/58 participants withdrew from the study. The clinical importance is unknown (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.44. Indentation load deflection (IDL) (25%) operating room foam mattress (density 1.3 cubic feet, IDL 30lb) versus operating room usual care (padding as required, including gel pads, foam mattresses, ring cushions (donuts))
  • One study (n=413) showed an indentation load deflection operating room foam mattress has a potential for clinical harm at reducing the incidence of pressure ulcers (all grades) when compared to operating room usual care (low quality).
  • One study (n=413) showed that there was potentially no clinical difference of an indentation load deflection operating room foam mattress compared to operating room usual care for reducing the incidence of pressure ulcers (grade 2 and above), but the direction of the estimate of effect favoured usual care (very low quality).
  • One study (n=413) reported that participants on the indentation load deflection operating room foam mattress were significantly more likely to have skin changes than those on the usual care operating room table. The clinical importance is unknown (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.45. Viscoelastic polymer pad versus no overlay
  • One study (n=416) showed a viscoelastic polymer pad is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades of pressure ulcers) when compared to no overlay (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.46. Viscoelastic foam overlay versus no overlay
  • One study (n=175) showed there may be no clinical difference for a viscoelastic foam overlay compared to no overlay for reducing the incidence of pressure ulcers (all grades), the direction of the estimate of effect favoured the viscoelastic foam overlay (very low quality).
  • One study (n=175) showed there may be no clinical difference between viscoelastic foam overlay and no overlay for reducing the incidence of pressure ulcers (grade 2 and above), but the direction of the estimate of effect could favour either intervention (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.47. Neoprene air filled bladder (dry flotation) device compared to a disposable polyurethane foam prone head positioner
  • One study (n=44) showed there is potentially a clinical benefit for a neoprene air filled bladder (dry flotation) device compared to a disposable polyurethane foam prone head positioner for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • One study (n=44) showed there may be a clinical benefit for a neoprene air filled bladder (dry flotation) device compared to a disposable polyurethane foam prone head positioner for reducing the incidence of pressure ulcers (grade 2and above) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.48. A prone view protective helmet system with a disposable polyurethane foam prone head positioner versus a disposable polyurethane foam prone head positioner
  • One study (n=44) showed a prone view protective helmet system with a disposable polyurethane foam prone head positioner has a potential for clinical benefit for reducing the incidence of pressure ulcers (all grades) when compared to a disposable polyurethane foam prone head positioner (very low quality).
  • One study (n=44) showed there may be a clinical benefit for a prone view protective helmet system with a disposable polyurethane foam prone head positioner compared to a disposable polyurethane foam prone head positioner for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.49. A neoprene air filled bladder (dry flotation) device versus a prone view protective helmet system with a disposable polyurethane foam prone head positioner
  • One study (n=44) showed there is no clinical difference between a neoprene air filled bladder (dry flotation) device and a prone view protective helmet system with a disposable polyurethane foam prone head positioner for reducing the incidence of pressure ulcers (all grades) (low quality).
  • One study (n=44) showed there is no clinical difference between a neoprene air filled bladder (dry flotation) device and a prone view protective helmet system with a disposable polyurethane foam prone head positioner for reducing the incidence of pressure ulcers (grade 2 and above) (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.1.50. A multi-cell pulsating dynamic mattress versus a standard mattress
  • Two studies (n=368) showed that for people undergoing surgery, a multi-cell pulsating dynamic mattress system is more clinically effective at reducing the incidence of pressure ulcers (all grades) when compared to a standard mattress (low quality).
  • One study (n=170) showed that for people undergoing surgery, a multi-cell pulsating dynamic mattress system is potentially more clinically effective at reducing the incidence of pressure ulcers (grade 2 and above) when compared to a standard mattress (very low quality).
  • One study (n=170) reported information about the length of stay in hospital for people who developed pressure ulcers. The average length of stay for those developing pressure ulcers was 14 days. Six of the 8 people who developed ulcers had a length of stay longer than average for the specific diagnosis. The clinical importance is unknown (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Health related quality of life
12.1.14.1.51. A visco-elastic foam accident and emergency (A&E) overlay and ward mattress versus standard A&E overlay and ward mattress
  • One study (n=101) showed there may be a clinical benefit for visco-elastic foam A&E overlay and ward mattress compared to a standard A&E overlay and ward mattress for reducing the incidence of pressure ulcers (grade 2 and above) (very low quality).
  • One study (n=101) showed there may be a clinical benefit for visco-elastic foam A&E overlay and ward mattress compared to standard A&E overlay and ward mattress for reducing the incidence of pressure ulcers (all grades) (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life

12.1.14.2. Wheelchair cushions

12.1.14.2.1. Slab foam cushion versus bespoke contoured foam cushion
  • Two studies (n=300) showed there is no clinical difference between a slab foam cushion when compared with a bespoke contoured foam cushion for reducing the incidence of pressure ulcers (all grades) (low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.2.2. Gel cushion with foam base (JAY) versus foam cushion
  • One study (n=141) showed a gel cushion with foam base is potentially more clinically effective at reducing the incidence of pressure ulcers (all grades of pressure ulcers) when compared to a foam cushion (low quality).
  • One study (n=163) showed there may be a clinical benefit for a gel cushion with foam base compared to a foam cushion for patient acceptability (withdrawal due to discomfort) (very low quality).
  • No evidence was found for the following outcomes:
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.2.3. Pressure reducing cushion (not specified – chosen by nurse based on the individual) versus standard 3 inch convoluted foam cushion (EGGRATE)
  • One study (n=32) showed there may be a clinical benefit for a pressure reducing cushion compared to a standard 3 inch convoluted foam cushion for reducing the incidence of pressure ulcers (all grades), (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life
12.1.14.2.4. Skin protection cushion versus segmented foam cushion
  • One study (n=232) showed a skin protection cushion is potentially more clinically effective at reducing the incidence of sitting related ischial tuberosities when compared to a segmented foam cushion (very low quality).
  • One study (n=232) showed a skin protection cushion is potentially more clinically effective at reducing the incidence of pressure ulcers of the combined ischial tuberosities and sacral/coccyx areas when compared to a segmented foam cushion (very low quality).
  • No evidence was found for the following outcomes:
    • Patient acceptability
    • Rates of development of pressure ulcers
    • Time to develop new pressure ulcers
    • Time in hospital or NHS care
    • Health related quality of life

12.1.14.3. Economic (adults)

12.1.14.3.1. Alternating pressure verses alternative foam
  • One cost–utility analysis found that alternating pressure overlays and alternating pressure mattress replacements dominate (less costly and more effective) high specification foam mattresses in the prevention of pressure ulcers. This analysis was assessed as partially applicable with potentially serious limitations.
12.1.14.3.2. Comparisons between alternating pressure devices
  • One cost–utility analysis found that alternating pressure mattress replacements were not cost effective compared to alternating pressure overlays for the prevention of pressure ulcers (ICER: £253,000 per QALY gained). This analysis was assessed as partially applicable with potentially serious limitations.
  • Conversely, 1 cost-effectiveness analysis found alternating pressure mattress replacements dominate alternating overlays, with a longer time to pressure ulcer development and reduced costs. This analysis was assessed as partially applicable with potentially serious limitations.
12.1.14.3.3. High specification foam verses standard practice
  • One cost–effectiveness analysis found that high specification foam mattresses dominate standard mattresses in the prevention of pressure ulcers, with a reduced incidence of pressure ulcers at a lower cost. This analysis was assessed as partially applicable with minor limitations.
  • One cost–utility analysis found that use of pressure redistribution foam mattresses (for all residents) dominates standard practice in the prevention of pressure ulcers, with an increase in QALYs at a lower cost. This analysis was assessed as partially applicable with potentially serious limitations
  • One cost-effectiveness analysis found that visco-polymer energy absorbing foam mattresses dominate standard mattresses, with reduced costs and reduced incidence of pressure ulcer. This analysis was assessed as partially applicable with minor limitations.
12.1.14.3.4. Constant low pressure supports compared to standard care
  • One cost–effectiveness analysis found that usual care plus Australian medical sheepskin was more costly and more effective than usual care alone (ICER: £2,298 per sacral pressure ulcer avoided). This analysis was assessed as partially applicable with potentially serious limitations.
  • One cost–effectiveness analysis found that a preventative treatment protocol and use of a Clinitron Rite-Hite Air Fluidised Therapy bed dominates standard care on an ICU bed (reduction in pressure ulcer incidence and reduced costs). This analysis was assessed as partially applicable with potentially serious limitations.
  • One cost–effectiveness analysis found that use of an inflated static overlay dominated (reduction in pressure ulcer incidence and reduced costs) standard care in the prevention of pressure ulcers. This analysis was assessed as partially applicable with potentially serious limitations.
12.1.14.3.5. Constant low pressure supports compared to standard care in operating theatre
  • One cost–utility analysis found that use of viscoelastic polymer overlays on operating tables (for people undergoing surgery expected to last ≥90 minutes) dominates current practice, yielding higher QALYs at a lower cost. This analysis was assessed as partially applicable with minor limitations.

12.1.14.4. Clinical (neonates, infants, children and young people)

No evidence was identified

12.1.14.5. Economic (neonates, infants, children and young people)

No evidence was identified

12.2. Recommendations and link to evidence

12.2.1. Adults

Image

Table

Use a high-specification foam mattress for adults who are: admitted to secondary care

12.2.2. Neonates, infants, children and young people

Image

Table

Use a high-specification foam cot mattress or overlay for all neonates and infants who have been identified as being at high risk of developing a pressure ulcer as part of their individualised care plan. Use a high-specification foam mattress or overlay (more...)

Image

Table

Offer infants, children and young people who are long-term wheelchair users, regular wheelchair assessments and provide pressure relief or redistribution.

Image

Table

Offer neonates, infants, children and young people at risk of developing an occipital pressure ulcer an appropriate pressure redistributing surface (for example, a suitable pillow or pressure redistributing pad).